World Compliance Laboratory(Guangdong) Co., Ltd.

The third party & the pathfinder of new certification mode
Testing and Certification
Professional, Authoritative, Customer Supreme
Hotline 400-888-2955

Current location:Home > News > Industry news

Contact us

Worldtest(GuangDong)Co., Ltd.


Address: Rooms 201 and 102,Building 6,No.6,North Industrial Road.Songshan Lake(SSL), Dongguan, Guangdong, China

Telphone::0769-22891258

FaX:0769-22891235

Emaile:service.vip@worldtest.cn

Website:www.worldtest.cn

www.worldtest.com.cn

ENERGY STAR (Lamp 2.0) Product Specification Requirements Change Description from Version 1.2 to Version 2.0

Time:2015-09-06 16:49:00 CTR:

The U.S. Environmental Protection Agency (EPA) has released the final version of the Energy Star Specification for lamps and lanterns version 2.0. The new specification and all requirements will take effect on June 1, 2016.

   1. Main time points:

  June 1, 2016: The effective date of version 2.0 of the fixture. All lamps must be re-certified before June 1, 2016, otherwise they will not appear on the Energy Star Qualified Product List (QPL).

  December 1, 2015: After December 1, 2015, all lamps must be tested and evaluated in accordance with the lamp version 2.0. Before December 1, 2015, the laboratory certification can use version 1.2 or version 2.0.

   2. Main changes:

  A, a new category has been added

  B, expand the scope of household lamps

  C, reduced test samples

  D, to make the requirements of the ENERGY STAR specification for lamps and lanterns version 2.0 more reasonable

  E, improve the light efficiency of directional products

  Added new categories

  Color adjustable products (at least one of the colors must be white)

  Non-directional diffuser modified wall lamp

  Non-directional diffuser modified ceiling surface mounted luminaire

  Lamp with screw socket

  Smart lamps (wireless communication)

  Summary of Changes in ENERGY STAR Lamp 2.0 Version

 

project

Lamps and lanterns version 1.2

Lamps and lanterns version 2.0

Household range

The wattage is not allowed to change

Allowable wattage changes during additional testing of changed lamps; each wattage must be listed separately

Household range

Additional required testing or data loss

According to the checklist guidelines need to specify the test or data

Lamp holder

Screw lamp holders (E26, E12, etc.) are not allowed

As long as there is a tube in the packaging of the lamp, it is allowed

Corridor lights

Only targeted categories allowed

Both targeted and non-targeted categories are allowed

Is there a light tube when shipped?

Some types of lamps are allowed to be shipped without lamps

The lamp holders of all lamps and lanterns must be equipped with lamp tubes during transportation

SSL retrofit kit safety checklist

Not clear

Must comply with ANSI/ UL1598C-2014 (modified)

    

Higher performance requirements for targeted categories

 

Targeted products

Lamps and lanterns version

Lamps and lanterns version2.0

Dark channel light

45 lm/W

50 lm/W

Spotlight

42 lm/W

55 lm/W

Modified spotlight

42 lm/W

60 lm/W

Bright lights

35 lm/W

55 lm/W

Cabinet Light

29 lm/W

50 lm/W

Outdoor wall lights, corridor lights, chandeliers, rear lights and safety lights

35 lm/W

60 lm/W

Portable table lamp

29 lm/W

50 lm/W

Non-detachable SSL light

70 lm/W

70 lm/W (same)


Number of test samples:

The sample size for the following tests remains unchanged: color angle uniformity, color maintenance rate, standby power consumption, maximum temperature of the ballast or driver housing, and LED light source temperature. The changes to the number of samples are shown in the following table:

 

Test

Lamps and lanterns version1.2

Lamps and lanterns version2.0

Correlated color temperature (CCT)

10 fluorescent lamps or 1 SSL lamp

1 fluorescent lamp or 1 SSL lamp

Color rendering index (CRI)

10 fluorescent lamps or 1 SSL lamp

1 fluorescent lamp or 1 SSL lamp

Luminous maintenance rate

10 fluorescent lamps or 1 SSL lamp

3 fluorescent lamps or 1 SSL lamp

Light source life

10 fluorescent lamps or 1 SSL lamp

3 fluorescent lamps or 1 SSL lamp

Light source start time

3 samples

1 samples

Light source increase time

3 fluorescent lamp

1 fluorescent lamp

Power factor

3 samples

At least 1 sample

Transient protection

3 samples

At least 1 sample

working frequency

3 samples

1 samples

Non-directional product light source efficacy

3 samples

1 samples

Dimming

3 samples

1 samples


About World
About us
Culture
Organizational Structure
Corporate Environment
Enterprise Equipment
Technical Team
Statement Of Fairness
Business scope
Electrical safety / Mechanical safety
Risk Assessment & Reduction
Functional safety
Electromagnetic compatibility
Performance testing
MORE
NEWS CENTER
Company news
Industry news
Training and seminars
Laws and regulations
FAQ
CONTACT US
Dongguan Songshanhu Testing Center
ADD:Rooms 201 and 102,Building 6,No.6,North Industrial Road.Songshan Lake(SSL), Dongguan, Guangdong, China
TEL:0769-22891258
FAX:0769-22891235
EMAIL: service.vip@worldtest.cn
consultation
微信
copyright ©World Compliance Laboratory(Guangdong) Co., Ltd.     Record number:粤ICP备16022345号 Technical Support:Dongguan website construction
Language

Service hotline

400-888-2955

WeChat